Air within the aneurysm sac following endovascular management of abdominal aortic aneurysm in a patient with acute pancreatitis
    PDF
    Cite
    Share
    Request
    Interventional Radiology - Case Report 2016
    P: 153-156
    June 2009

    Air within the aneurysm sac following endovascular management of abdominal aortic aneurysm in a patient with acute pancreatitis

    Diagn Interv Radiol 2009;15(2):153-156
    1. Departments of Radiology, İnönü University School of Medicine, Malatya, Turkey
    2. Departments of Cardiovascular Surgery, İnönü University School of Medicine, Malatya, Turkey
    No information available.
    No information available
    Received Date: 31.08.2007
    Accepted Date: 08.12.2007
    PDF
    Cite
    Share
    Request

    ABSTRACT

    A 44-year-old man with an abdominal aortic aneurysm presented with acute pancreatitis with abundant peripancreatic fluid and was successfully treated with endovascular stent graft. Early post-procedural radiological examinations showed air inside the aneurysm sac. Due to the possible infection from pancreatitis, antibiotic treatment was initiated, and he was closely monitored. Serial radiological examinations showed gradual decrease and eventual resolution of air at the end of one month. Follow-up computed tomography 10 months post-implantation revealed no problems. The presence of air inside the aneurysm sac could be a sign of graft infection. Although the air usually resolves spontaneously, close surveillance is necessary for cases with higher risk of infection.

    Keywords: aortic aneurysm, abdominal, stent-graft, pancreatitis, infection