CT colonography has low sensitivity but high specificity in the detection of internal hemorrhoids
    PDF
    Cite
    Share
    Request
    Abdominal Radiology - Original Article
    P: 82-86
    March 2020

    CT colonography has low sensitivity but high specificity in the detection of internal hemorrhoids

    Diagn Interv Radiol 2020;26(2):82-86
    1. Department of Radiology, First School of Medicine Charles University and General University Hospital in Prague, Prague, Czech Republic
    2. Fourth Department of Medicine, First School of Medicine Charles University and General University Hospital in Prague, Prague, Czech Republic
    No information available.
    No information available
    Received Date: 22.02.2019
    Accepted Date: 02.08.2019
    PDF
    Cite
    Share
    Request

    ABSTRACT

    PURPOSE

    We aimed to evaluate the diagnostic performance of computed tomography colonography (CTC) in the detection of internal hemorrhoids.

    METHODS

    Three gastroenterologists systematically reported on the presence of internal hemorrhoids in patients with incomplete colonoscopy, for whom they considered a subsequent CTC. For 44 patients with internal hemorrhoids revealed by optical colonoscopy, an age- and gender-matched cohort of 66 patients with normal findings in the rectum was selected. Endoluminal and transaxial CTC views of the rectum were evaluated for the presence of internal hemorrhoids, the anal verge prominence, asymmetry, and cushion-like appearance on a Likert scale by two experienced radiologists and two gastroenterologists.

    RESULTS

    The sensitivity, specificity, and AUC for identification of internal hemorrhoids were 0.61 (95% CI, 0.53–0.68), 0.69 (95% CI, 0.63–0.75) and 0.66 (95% CI, 0.62–0.70), respectively. The radiologists showed a better specificity, the gastroenterologists a slightly better sensitivity. When only the rating “very likely” was considered as positive, the specificity rose to 0.89 (95% CI, 0.81–0.94) with a sensitivity of 0.50 (95% CI, 0.38–0.62). The interobserver agreement was fair. The best predictor of the presence of hemorrhoids was a prominent anal verge in the supine position (OR=1.789, 95% CI, 1.267–2.525). The difference between supine and prone positions in the evaluated features in patients with internal hemorrhoids was not significant.

    CONCLUSION

    CTC has low sensitivity but high specificity in the detection of internal hemorrhoids, if the rater is confident in detecting them. Internal hemorrhoids do not substantially change their shape between prone and supine positions.

    References

    2024 ©️ Galenos Publishing House