Liver stiffness value obtained by point shear-wave elastography is significantly related with atrial septal defect size
    PDF
    Cite
    Share
    Request
    Cardiovascular Imaging - Original Article
    P: 284-291
    July 2020

    Liver stiffness value obtained by point shear-wave elastography is significantly related with atrial septal defect size

    Diagn Interv Radiol 2020;26(4):284-291
    1. Department of Cardiology, University of Health Sciences Adana Health Practice and Research Center, Adana, Turkey
    2. Department of Radiology, University of Health Sciences Adana Health Practice and Research Center, Adana, Turkey
    3. Department of Internal Medicine, University of Health Sciences Adana Health Practice and Research Center, Adana, Turkey
    No information available.
    No information available
    Received Date: 14.05.2019
    Accepted Date: 17.11.2020
    PDF
    Cite
    Share
    Request

    ABSTRACT

    PURPOSE

    The increase in volume and pressure in the right atrium (RA) and right ventricle (RV) has been shown to increase the liver stiffness (LS). In the literature, there is no information about the changes in LS value in patients with atrial septal defect (ASD). The aim of our study was to investigate the change of LS values obtained by point shear-wave elastography (pSWE) in patients with ASD and the clinical utility of pSWE for this disease.

    METHODS

    This cross-sectional study included 66 patients with ostium secundum ASD: 21 patients with no indication for ASD closure (Group I), 38 patients who underwent ASD closure (Group II), and 7 patients who had ASD with Eisenmenger syndrome (Group III). All patients underwent echocardiography and pSWE. Increased LS was accepted as ≥7 kPa.

    RESULTS

    LS values as well as transaminases, clinical signs of heart failure and functional and structural heart abnormalities (increase of RA and RV diastolic dimensions, tricuspid regurgitation pressure gradient [TRPG], ASD size and decrease of ejection fraction, tricuspid annular plane systolic excursion) significantly increased from Group I to Group III (P < 0.001 for all comparisons). Mean LS values for Group I, Group II, and Group III were 5.16±1.55 kPa, 7.48±1.99 kPa, and 13.9±2.58 kPa, respectively. In multivariate linear regression analysis, ASD size and TRPG were significantly associated with LS increase. Only ASD size independently predicted abnormal LS increase ≥7 kPa according to multivariate logistic regression. Clinical value of LS increase was comparable to TRPG for detection of Eisenmenger syndrome; in the receiver operating curve analysis, area under the curve was 0.995 for LS (P < 0.001) and 0.990 for TRPG (P < 0.001). At 10 kPa threshold, LS determined the Eisenmenger syndrome with 100% sensitivity and 91.5% specificity.

    CONCLUSION

    LS value assessed by pSWE was significantly increased in ASD patients with closure indication and Eisenmenger syndrome compared to patients without ASD closure indication and was comparable with TRPG in regards to Eisenmenger syndrome identification. ASD size significantly associated with LS and independently predicted abnormal LS increase ≥7 kPa.

    References

    2024 ©️ Galenos Publishing House