Percutaneous core needle biopsy for small (≤10 mm) lung nodules: accurate diagnosis and complication rates
PDF
Cite
Share
Request
Chest Imaging - Original Article
P: 527-530
November 2012

Percutaneous core needle biopsy for small (≤10 mm) lung nodules: accurate diagnosis and complication rates

Diagn Interv Radiol 2012;18(6):527-530
1. Departments of Radiology, Hallym University College of Medicine, Chuncheon, Republic of Korea
2. Departments of Occupational Medicine, Hallym University College of Medicine, Chuncheon, Republic of Korea.
No information available.
No information available
Received Date: 10.01.2012
Accepted Date: 18.04.2012
PDF
Cite
Share
Request

ABSTRACT

PURPOSE

To evaluate accurate diagnosis and complication rates of percutaneous core needle biopsy (PCNB) with an automated gun for small lung nodules that are 10 mm or less in diameter.

MATERIALS AND METHODS

Forty-two cases of small lung nodules with diameters ≤10 mm (mean diameter, 9 mm) that received a PCNB were included in this study. Imaging guidance was fluoroscopy in 30 cases and computed tomography (CT) in 12 cases.

RESULTS

Accurate diagnosis was achieved with the initial PCNB in 88.1% (37/42) of cases. Accurate diagnosis rates were 86.7% (26/30) with fluoroscopic guidance and 91.7% (11/12) with CT guidance (P > 0.05). The complication rate of PCNB was 7.1% (3/42), including hemoptysis (n=2) and pneumothorax (n=1). The complication rate was 6.7% (2/30) with fluoroscopic guidance and 8.3% (1/12) with CT guidance (P > 0.05).

CONCLUSION