Vacuum-assisted stereotactic biopsy for isolated BI-RADS 4 microcalcifications: evaluation with histopathology and midterm follow-up results
    PDF
    Cite
    Share
    Request
    Breast Imaging - Original Article
    P: 22-27
    January 2015

    Vacuum-assisted stereotactic biopsy for isolated BI-RADS 4 microcalcifications: evaluation with histopathology and midterm follow-up results

    Diagn Interv Radiol 2015;21(1):22-27
    1. Department of Radiology, Maltepe University School of Medicine, Istanbul, Turkey
    2. Department of Radiology, FSM Research and Training Hospital, Istanbul, Turkey
    3. Department of General Surgery, Maltepe University School of Medicine, Istanbul, Turkey
    4. Department of Pathology, Maltepe University School of Medicine, Istanbul, Turkey
    No information available.
    No information available
    Received Date: 16.01.2014
    Accepted Date: 01.07.2014
    PDF
    Cite
    Share
    Request

    ABSTRACT

    PURPOSE

    The aim of this study was to evaluate the 10-gauge vacuum-assisted stereotactic biopsy (VASB) of isolated Breast Imaging Reporting and Data System (BI-RADS) 4 microcalcifications, using histology and follow-up results.

    METHODS

    From January 2011 to June 2013, VASB was performed on 132 lesions, and 66 microcalcification-only lesions of BI-RADS 4 were included into our study. VASB was performed using lateral decubitis stereotaxy for all patients. Pathologic results of VASB and further surgical biopsies were reviewed retrospectively. Patients who were diagnosed to have benign lesions by VASB were referred for follow-up. VASB and surgical histopathology results were compared to determine the underestimation ratios.

    RESULTS

    Fifteen out of 66 lesions from 63 patients (median age, 47 years; range, 34–88 years) were identified as malignant by VASB. Pathological results after surgery revealed three cases of invasive ductal carcinoma among the 12 VASB-diagnosed ductal carcinoma in situ (DCIS) lesions, for a DCIS underestimation rate of 25%. The atypical ductal hyperplasia underestimation rate was 0% for the three lesions. The follow-up period was at least 10 months, with an average of 22.7 months for all patients and 21.2 months for patients with VASB-diagnosed benign lesions. None of the patients had malignancy during the follow-ups. The false-negative rate was 0% in the follow-up of 48 patients.

    CONCLUSION

    VASB should be the standard method of choice for BI-RADS 4 microcalcifications. This method obviates the need for a surgical procedure in 73% of BI-RADS 4 microcalcification-only patients.