A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
PDF
Cite
Share
Request
Interventional Radiology - Case Report 2016
P: 73-75
January 2013

A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm

Diagn Interv Radiol 2013;19(1):73-75
1. Vascular and Endovascular Surgery Unit, University of Palermo, Palermo, Italy
2. Department of Diagnostic Imaging, Section of General and Emergency Radiology, Cardarelli Hospital of Naples, Naples, Italy
No information available.
No information available
Received Date: 08.01.2012
Accepted Date: 18.04.2012
PDF
Cite
Share
Request

ABSTRACT

We described a modi…ed technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation.