Pulmonary adenocarcinomas presenting as ground-glass opacities on multidetector CT: three-dimensional computer-assisted analysis of growth pattern and doubling time
PDF
Cite
Share
Request
Chest Imaging - Original Article
P: 525-533
November 2016

Pulmonary adenocarcinomas presenting as ground-glass opacities on multidetector CT: three-dimensional computer-assisted analysis of growth pattern and doubling time

Diagn Interv Radiol 2016;22(6):525-533
1. Department of Radiology, University and Spedali Civili of Brescia, Italy
2. Thoracic Surgery Unit, University and Spedali Civili of Brescia, Italy
3. Department of Pathology, University and Spedali Civili of Brescia, Italy
No information available.
No information available
Received Date: 27.02.2016
Accepted Date: 08.06.2016
PDF
Cite
Share
Request

ABSTRACT

PURPOSE:

We aimed to evaluate the growth pattern and doubling time (DT) of pulmonary adenocarcinomas exhibiting ground-glass opacities (GGOs) on multidetector computed tomography (CT).

METHODS:

The growth pattern and DT of 22 pulmonary adenocarcinomas exhibiting GGOs were retrospectively analyzed using three-dimensional semiautomatic software. Analysis of each lesion was based on calculations of volume and mass changes and their respective DTs throughout CT follow-up. Three-dimensional segmentation was performed by a single radiologist on each CT scan. The same observer and another radiologist independently repeated the segmentation at the baseline and the last CT scan to determine the variability of the measurements. The relationships among DTs, histopathology, and initial CT features of the lesions were also analyzed.

RESULTS:

Pulmonary adenocarcinomas presenting as GGOs exhibited different growth patterns: some lesions grew rapidly and some grew slowly, whereas others alternated between periods of growth, stability, or shrinkage. A significant increase in volume and mass that exceeded the coefficient of repeatability of interobserver variability was observed in 72.7% and 84.2% of GGOs, respectively. The volume-DTs and mass-DTs were heterogeneous throughout the follow-up CT scan (range, -4293 to 21928 and -3113 to 17020 days, respectively), and their intra- and interobserver variabilities were moderately high. The volume-DTs and mass-DTs were not correlated with the initial CT features of GGOs; however, they were significantly shorter in invasive adenocarcinomas (P = 0.002 and P = 0.001, respectively).

CONCLUSION:

Pulmonary adenocarcinomas exhibiting GGOs show heterogeneous growth patterns with a trend toward a progressive increase in size. DTs may be useful for predicting tumor aggressiveness.