Risk factors for hemoptysis complicating 17-18 gauge CT-guided transthoracic needle core biopsy: multivariate analysis of 249 procedures
    PDF
    Cite
    Share
    Request
    Chest Imaging - Original Article
    P: 347-353
    September 2017

    Risk factors for hemoptysis complicating 17-18 gauge CT-guided transthoracic needle core biopsy: multivariate analysis of 249 procedures

    Diagn Interv Radiol 2017;23(5):347-353
    1. Department of Radiology, Paris Descartes University, Sorbonne Paris Cité Groupe Hospitalier Cochin-Hotel Dieu, Paris, France.
    2. Department of Biostatistics and Epidemiology, Paris Descartes University, Sorbonne Paris Cité Groupe Hospitalier Cochin-Hotel Dieu, Paris, France.
    3. Department of Thoracic Surgery, Paris Descartes University, Sorbonne Paris Cité Groupe Hospitalier Cochin-Hotel Dieu, Paris, France.
    No information available.
    No information available
    Received Date: 26.07.2016
    Accepted Date: 14.04.2017
    PDF
    Cite
    Share
    Request

    ABSTRACT

    Purpose:

    We aimed to identify modifiable and nonmodifiable risk factors for hemoptysis complicating computed tomography (CT)-guided transthoracic needle biopsy.

    Methods:

    All procedures performed in our institution from November 2013 to May 2015 were reviewed. Hemoptysis was classified as mild if limited to hemoptoic sputum and abundant otherwise. Presence of intra-alveolar hemorrhage on postbiopsy CT images was also evaluated. Patient- and lesion-related variables were considered nonmodifiable, while procedure-related variables were considered modifiable.

    Results:

    A total of 249 procedures were evaluated. Hemoptysis and alveolar hemorrhage occurred in 18% and 58% of procedures, respectively, and were abundant or significant in 8% and 17% of procedures, respectively. Concordance between the occurrence of significant alveolar hemorrhage (grade ≥2) and hemoptysis was poor (κ=0.28; 95% CI [0.16–0.40]). In multivariate analysis, female gender (P = 0.008), a longer transpulmonary needle path (P = 0.014), and smaller lesion size (P = 0.044) were independent risk factors for hemoptysis. Transpulmonary needle-path length was the only risk factor for abundant hemoptysis with borderline statistical significance (P = 0.049).

    Conclusion:

    The transpulmonary needle path should be as short as possible to reduce the risk of abundant hemoptysis during CT-guided transthoracic needle biopsy.